ES1_OSC=Val_0x0, ES0_OSC=Val_0x0, ES1_PLL=Val_0x0, ES0_PLL=Val_0x0
Clock Select Register for M55-HP and M55-HE
ES0_PLL | Select PLL clock frequency for RTSS_HP_CLK 0 (Val_0x0): Select 100 MHz PLL clock 1 (Val_0x1): Select 200 MHz PLL clock 2 (Val_0x2): Select 300 MHz PLL clock 3 (Val_0x3): Select 400 MHz PLL clock |
ES1_PLL | Select PLL clock frequency for RTSS_HE_CLK 0 (Val_0x0): Select 60 MHz PLL clock 1 (Val_0x1): Select 80 MHz PLL clock 2 (Val_0x2): Select 120 MHz PLL clock 3 (Val_0x3): Select 160 MHz PLL clock |
ES0_OSC | Select oscillator clock frequency for RTSS_HP_CLK 0 (Val_0x0): Select 76.8 MHz ring-oscillator clock 1 (Val_0x1): Select 38.4 MHz ring-oscillator clock 2 (Val_0x2): Select 76.8 MHz crystal-oscillator clock 3 (Val_0x3): Select 38.4 MHz crystal-oscillator clock |
ES1_OSC | Select oscillator clock frequency for RTSS_HE_CLK 0 (Val_0x0): Select 76.8 MHz ring-oscillator clock 1 (Val_0x1): Select 38.4 MHz ring-oscillator clock 2 (Val_0x2): Select 76.8 MHz crystal-oscillator clock 3 (Val_0x3): Select 38.4 MHz crystal-oscillator clock |